Home » Products » 7G - Hybrid Coolers » Hybrid Indirect Evaporative Air Cooler

Hybrid Indirect Evaporative Air Cooler

Hybrid Indirect Evaporative Air Cooler
Hybrid Indirect Evaporative Air Cooler
Send Inquiry
Product Code : KAAVA HiDEC-2K-7G
Price And Quantity
  • Minimum Order Quantity
  • 1
  • Unit of Measure
  • Unit/Units
  • Price
  • 30000 INR
Product Specifications
  • Product Type
  • Evaporative Air Cooler
  • Power Source
  • Electrical
  • Color
  • Grey
  • Usage
  • Industrial Use
  • Material
  • GI Sheet and Iron, Other
  • Voltage
  • 220 Volt (v)
Product Description

Hybrid Indirect Evaporative Air Cooler uses advantage of cooling using water evaporation without increasing humidity of supply air. It helps in reducing dry bulb temperature and enables its use in all climate zones. This hybrid cooler couples conventional mechanical cooling with evaporative cooling techniques that helps to reduces compressor electricity demand and consumption. Its each component can operate independently or simultaneously, according to ambient conditions and cooling demands. In indirect method, air is passed over water coils to pass heat from air to water. Hybrid Indirect Evaporative Air Cooler is highly efficient and excellent quality cooler suitable for use in scorching summers.

 

 

 

Working Principle

Working flow is divided into many small flows which pass the dry channels in the lower part of the cooling core. Every small flow is cooled by all the small flows before it crosses pass in another side channels called "wet channels".

Dry and wet channels are placed one by one with thinner wall separately made of special materials. Heat transfers but no water exchanges. Working flows are cooled down but no moisture added. Then every flow goes into wet channels placed its two sides by through its controlling holes, contact with the counter-flow water. It is cooled and moisture added. Then bring the heat passed from its two-side. Its temperature is lowed down continuously at the end; its temperature goes under the web-bulb of its beginning flow, near the dew-point temperature.

Supplying flow also is divided into many small flows, go through the dry channels placed in the part of the core. They are cooled by their own two-side working flows crossing flow in the wet channels. No any moisture is added, but the temperature is cooled down under the wet-bulb of its beginning flow.

Features

  • High Efficiency: COP > 30
  • 0% Moisture Addition
  • Maximum Cooling Efficiency
  • Intelligent Control
  • Group Control
  • Easy Maintenance
  • Environment Friendly

Applications

  • Data Center
  • Research center
  • Computer room
  • Transportation Hub
  • Exhibition center
  • Apartments house
  • Hotel and Hospital.
Trade Information
  • Payment Terms
  • Paypal, Western Union, Telegraphic Transfer (T/T), Letter of Credit at Sight (Sight L/C), Letter of Credit (L/C), Delivery Point (DP), Days after Acceptance (DA), Cheque, Cash in Advance (CID), Cash Advance (CA), Cash on Delivery (COD), Cash Against Delivery (CAD)
  • Supply Ability
  • 500 Unit Per Month
  • Delivery Time
  • 2-3 Week
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Main Export Market(s)
  • Africa, Middle East, Western Europe, Eastern Europe, South America, North America, Central America, Australia, Asia
  • Main Domestic Market
  • All India